Filtration Equipment

FRP-Series

Fiberglass Pressure Adsorbers

Resistant to many chemicals, GENERAL CARBON'S FRP-Series Liquid Phase Adsorbers are ideal where corrosion is a primary concern. Rated for 150 PSI, these units can be used effectively in high pressure applications where there is NO chance of a vacuum condition. The FRP-Series tanks come in many sizes to handle a full range of liquid flows. Made with an internal bladder wrapped in fiberglass, these filament wound vessels are ideal for filtration using activated carbon, resins or other filter media. Food grade internals are standard along with a wide selection of inlet/outlet sizes. Easy use automatic valves are available for unattended operation.

Standard Features
  • 150 PSI High Pressure Tank Design
  • Corrosion Resistant FRP Construction
  • ANSI/NSF Certifications
  • Food Grade Rating For Tank & Internals
  • Large Size Selection to Fit Any Project
Specifications
  Flow1 Carbon Tot. Vol. Inlet/Outlet    
Model No.

GPM

lbs2

Gallons

Location

FPT

Diameter

OAH
FRP-12x48 4 55 20.6 Top ¾” 12" 48"
FRP-13x54 5 75 27.5 Top 1" 13" 55"
FRP-16x65 10 130 49.0 Top 1" 16" 66"
FRP-18x65
12 180 66.8 Top 1" 18" 67"
FRP-24x72 15 330 118.5 T/B 1" 24" 76"
FRP-30x72 25 525 191.3 T/B 2" 30" 81"
FRP-36x72 35 780 218.0 T/B 2" 36" 82"
FRP-42x72 48 970 348.0 T/B 2" 42" 86"

FRP-48x72

62 1300 464.0 T/B 2" 48" 86"

 

  1. Flow Rate at Maximum Recommended Loading of 5 gpm/sq ft Bed Cross Section Area.
  2. Pounds of Carbon is for Density of 28#/cu. ft. and allowing 25% Bed Expansion for Backwash.

Installation & Start Up

FRP-Series adsorbers are shipped empty along with the required carbon. The adsorber should be connected and all fittings pressure tested for leaks before the carbon is installed through the top access hole. A vacuum relief device is advised to prevent tank damage. After the carbon has been loaded, the unit should be filled with clean water through the bottom collector, and allowed to degas for 8-12 hours if possible. Backwashing the carbon is recommended to remove carbon fines that can cause excessive pressure drop through the unit.

Maintenance

The only maintenance that FRP-Series adsorbers require is the testing of effluent quality, and the checking of the operating pressure of the system. Monitoring the contaminant level into the last unit in a series arrangement is the recommended safeguard against having breakthrough in the final outflow.

Servicing FRP-Tanks

Once an adsorber's carbon is saturated by contaminants, the unit should be taken off line and fresh carbon installed. To purchase replacement carbon or to arrange for a carbon change out, please contact our office. When preparing the unit to be serviced, as much water as possible should be drained from the vessel.



Caution!
Wet activated carbon removes oxygen from air causing a severe hazard to workers inside carbon vessels. Confined space/low oxygen procedures should be put in place before any entry is made. Such procedures should comply with all applicable local, state and federal guidelines.

Activated Carbon MSDS

> View the Activated Carbon MSDS